Seleccione su país/región en el menú o haciendo clic en el mapa *
Country Selector Alternate Image
Eficiencia Energética

                                                                                    Critical power protection for medium to large Data Centers

                                                                                     

                                                                                     

                                                                                     

                                                                                     


                                                                                     

                                                                                     

                                                                                    Value proposition


                                                                                    Main drivers

                                                                                    • Data center market is the largest market for critical power applications
                                                                                    • Data centers are also a large contributor to CO2 emission (1,5% of US power) and this is in constant increase.
                                                                                    • Electricity costs are also a key contributor to the CAPEX of a data center.

                                                                                    Solution in brief
                                                                                    • Critical Power Protection for Medium to Large Data Centers with high efficiency.
                                                                                    • Including Uninterrupted Power Supplies (UPS), Source Transfer Switches, Synchronization Modules, etc.
                                                                                    • Working according to recommended architectures towards optimum dependability.

                                                                                    Value proposition

                                                                                    • UPSs and associated equipment form high-availability configurations that are assembled in architectures compliant with the required availability standards (from 99,9979% to 99,9999% ("six nines")).
                                                                                    • UPS being in redundancy, they are not 100% loaded and it is critical to keep high-efficiency of the UPS even at low loads.  Galaxy 6000 has a 92% efficiency even at 25% load; at 500kVA a 2% efficiency level gain is worth €50,000 over 5 years in electricity cost!
                                                                                    • On non-linear loads THM option can help save an additional 20% on electricity bill

                                                                                    Differentiation factors

                                                                                    • Thanks to the combination of high-efficiency at low loads, and predefined architectures compliant with the de-facto "Tiers" levels, these systems provide an optimum combination of certified high availability and energy savings.
                                                                                     

                                                                                    Arquitectura de la aplicación EE

                                                                                    Arquitectura de la aplicación EE
                                                                                     

                                                                                    Main Energy Efficiency characteristics


                                                                                    Great Power quality

                                                                                    • Double-conversion 3 phase UPS with input harmonics filtering options from 12 pulse to phase shifting via passive filters
                                                                                    • Low thdu
                                                                                    • Output power factor: 0,8.

                                                                                    Great power availability

                                                                                    • Automatic and manual by-pass integrated, testing, monitoring and expected life time of batteries
                                                                                    • Fan failure detection on automatic by-pass
                                                                                    • High short circuit capacities.

                                                                                    Great flexibility

                                                                                    • 50 or 60 Hz, 380, 400, 415, 440, 480 volts
                                                                                    • Frequency converter, modular paralleling (up to 4), paralleling with centralized static switch (up to 6).

                                                                                    Total cost of ownership

                                                                                    • Optimized footprint via a true front access
                                                                                    • Optimized running costs via high efficiency: up to 95%.

                                                                                    Ease of management
                                                                                    • Vision display providing comfort (tactile, color), energy flow, measurements, statistics, events time stamping.
                                                                                    • Remote monitoring: via different protocole: J-Bus/Mod-Bus, Ethernet, volt free contacts.
                                                                                     
                                                                                     
                                                                                     
                                                                                     

                                                                                    Información adicional 

                                                                                    Solicite información de nuestras soluciones

                                                                                    Contacte con Schneider Electric
                                                                                     

                                                                                    Solution breakdown

                                                                                    • Main Services:
                                                                                      _
                                                                                      Design : Site audit, Protection system architecture and maintenance strategy advice, Harmonics audit
                                                                                      _ Implementation: installation, commissioning
                                                                                      _ Operation: Project management, Preventative maintenance, Maintenance contracts, Teleservice , Battery Monitoring, Training, ...
                                                                                      _ Review: Battery replacement, replacement program...
                                                                                    • Main Products & Systems
                                                                                      _
                                                                                      UPS: MGE Galaxy, MGE EPS (only in the US)
                                                                                      _ UPS with internal scalability: APC Symmetra
                                                                                      _ 3phase STS: Upsilon STS
                                                                                      _ Active harmonic filter: THM, Sinewave
                                                                                      _ Synchronization module
                                                                                      _ PDUs
                                                                                      _ Management and supervision: Enterprise Power Manager, InfrastruXure Central,...