                                                                                    Coordinated surge protection for distributed loads

                                                                                     

                                                                                     

                                                                                     

                                                                                    Value proposition


                                                                                    Customer drivers
                                                                                    • Critical Power architectures consider 2 levels of criticality:
                                                                                      - Critical loads, that do not accept any cut. 
                                                                                        In Data Center: servers.
                                                                                      - Important loads, that do not accept breve cuts. 
                                                                                        In Data Center: computer room air conditioning, during more than 10' ; industrial process, etc.
                                                                                    • Challenging Data Centers architectures has highlighted that important loads are more exposed to indirect lightning effects.

                                                                                    Solution in brief
                                                                                    • The risk can be radically reduced with an appropriated surge protection coordinated system:
                                                                                      - A type I protection: installed in the Main LV panelboard that conducts a direct lightning current.

                                                                                      - A type II protection: installed closed to the load to protect (less than 30 meters), that lower the protection level and ensure its compatibility with the impulse withstand voltage.
                                                                                    • SP_Canalis is the way for realizing this coordinated system in case of busway-supplied loads.

                                                                                    Value for the end user: reinsurance and safety
                                                                                    • Peace of mind: One manufacturer equipment qualified and certified.
                                                                                    • Safety: combination of MCB and SPD eliminates the risk of SPD explosion.
                                                                                    • Qualified solution: iFlexPower is a ‘key Component' of Critical Power architectures, associated to a coordinated surge protection system. In Data Center, it can improve per factor 71,6 the availability in case of lightning. 
                                                                                    • Size reduced.

                                                                                    Value for the engineering: simplicity and security

                                                                                    • Easy to prescribe: a simple configuration (only 3 x references / Busway range).
                                                                                    • Security: Surge arrester always effective due  to earth connection optimization.
                                                                                    • SP_Canalis facilitates installation specifications.

                                                                                    Value for the installer: confidence and serenity

                                                                                    • Easy to choose: Only 3 x references / Busway range.
                                                                                    • Easy to install: plug & play.
                                                                                    • Security: Surge arrester always effective due  to earth connection optimization.
                                                                                    • SP_Canalis facilitates installation precautions.
                                                                                     